wire [3:0] rd_idx = rd_addr[9:6];
wire [21:0] rd_tag = rd_addr[31:10];
+ reg [31:0] prev_rd_addr = 32'hFFFFFFFF;
+
wire cache_hit = cache_valid[rd_idx] && (cache_tags[rd_idx] == rd_tag);
always @(*) begin /* XXX does this work nowadays? */
bus_rd = 0;
end
- always @(posedge clk)
- if (rd_req && !cache_hit) begin
+ always @(posedge clk) begin
+ prev_rd_addr <= {rd_addr[31:6], 6'b0};
+ if (cache_fill_pos != 0 && ((prev_rd_addr != {rd_addr[31:6], 6'b0}) || cache_hit)) /* If this wasn't from the same line, or we've moved on somehow, reset the fill circuitry. */
+ cache_fill_pos <= 0;
+ else if (rd_req && !cache_hit) begin
if (bus_ready) begin /* Started the fill, and we have data. */
+ $display("ICACHE: FILL: rd addr %08x; bus addr %08x; bus data %08x", rd_addr, bus_addr, bus_rdata);
cache_data[rd_idx][cache_fill_pos] <= bus_rdata;
cache_fill_pos <= cache_fill_pos + 1;
if (cache_fill_pos == 15) begin /* Done? */
end
end
end
+ end
endmodule